Jacket covers entire gage and includes drawcords at each end for closure. Provided with openings for gage process connections, indicator and switches or transmitters.
Removable and reusable insulation jacket
All sewn seam construction
Custom fitted per gage
PTFE coated & impregnated fiberglass
1″ thickness to 550°F (287°C) (Standard)
2″ thickness to 800°F (426°C)
3″ thickness to 1000°F (537°C)
Stainless steel grommets
Polypropylene / fiberglass drawcord at ends
Cryogenic Insulation
Cryogenic insulation helps maintain cold process temperature and creates a moisture barrier to prevent ice buildup on the chamber or other items inside of the insulation.
32°F (0°C) to -250°F (-156°C)
Polyisocyanurate foam insulation – 2″ thick
.016″ Aluminum jacketing with moisture barrier
All joints to be sealed
Optional non frost extension required
Non-frost
Temperature Maintenance
Electric Heat Tracing
UL Approved, NEMA 4
Maximum exposure temperature = 375°F
Maximum maintenance temperature = 250°F
Thermostat available for temperature regulation
Optional Class I, Division I for use in hazardous locations
Steam Tracing
3/8″ OD tubing with 3/8″ OD compression end fittings